Decontaminating Kit, Skin: M258A1 and Training Aid, Skin Decontaminating: M58A1

Army · TM 3-4230-216-10 · 44 pages

Weight (filled): 3.2 oz (90.72 g) d. Operating Temperature: (0°C) to +110°F (43°C) NOTE • Although the normal operating temperature of the M258A1 is between and + 110ºF, the wipes will detoxify chemical agents at teperatures below and can…